Power Quality Inspection

Harm of power quality problems

Harmonic

It makes the components in the public power grid produce additional harmonic loss and reduces the efficiency of power generation, transmission and electrical equipment. When a large number of third harmonic flows through the neutral line, the line will overheat and even fire.Harmonic makes capacitors, cables and other equipment overheat, insulation aging, life shortened, and even damaged

Voltage fluctuation and flash edge

It leads to the downtime of electronic equipment, computer system and automatic control production line, which leads to the disorder of system control function with voltage phase angle as control instruction,It causes the motor speed instability and affects the product quality. In serious cases, the microcomputer equipment can operate safely

The voltage will be interrupted
temporarily and for a short time

It causes the trip of variable speed drive device, PLC damage, automatic control device misoperation, computer system malfunction and data loss, product quality off shelf and raw material loss caused by production line pause.The disordered start-up of equipment that causes disorder or interruption of production line and voltage drop is much more harmful and loss than the orderly recovery after planned power failure

Three phase voltage unbalance

When the transformer is in unbalanced operation, it will cause local overheating and reduce its service life. When the power supply line is in three-phase unbalanced system, the negative sequence current will produce additional loss and increase the line loss and voltage drop.For sensitive load, it may cause abnormal operation.


Application scenarios

电能质量检测业务(图1)
电能质量检测业务(图2)
电能质量检测业务(图3)

Service Items

Service Items
Power quality state detection and evaluation of power supply and distribution system
State detection and evaluation of power quality management equipment
Power quality inspection and evaluation of new energy equipment
Harmonic detection and evaluation of frequency conversion equipment
Commission test of new products
Technical research and consultation
System test items
Analysis of harmonic voltage and current
Analysis of three phase voltage unbalance
Frequency deviation analysis
Voltage deviation analysis
Analysis of long time and short time voltage fluctuation and flicker
Analysis of active power, reactive power, apparent power and power factor
Analysis of active impact and reactive impact
Test method
Product testing items
Harmonic compensation rate detection
Loss measurement
Dynamic response characteristic test
Detection of reactive power compensation rate
Temperature rise test
Electromagnetic compatiblity EMC
Effectiveness test of protection circuit
Protection level test
Short circuit strength test and short circuit protection function verification
Open phase protection test
Noise test
Technical research and consulting services
Fault diagnosis of power supply and distribution system
Micro grid design and planning consultation
Planning, design and consultation of power quality control equipment
Planning and design of power quality monitoring system
Planning and evaluation of user power quality limits


According to the standard

GB/T 12325-2008《电能质量 供电电压偏差》
GB/T 15945-2008《电能质量 电力系统频率偏差》
GB/T 15543-2008《电能质量 三相电压不平衡度》
GB/T 12326-2008《电能质量 电压波动和闪变》
GB/T 14549-1993《电能质量 公用电网谐波》
GB/T 24337-2009《电能质量 公用电网间谐波》
GB/T 19862-2005《电能质量 电能质量监测设备通用要求》
GB.Z 17625.4-2000/IEC61000-3-6:1996(TR2)《电磁兼容限值 中高压电力系统中畸变负荷发射限值的评估》


Case

Test point
Power Quality Inspection(图1)

Machinery manufacturing industry case

Customer issues:

Customers are large-scale manufacturing enterprises, with a large number of impact loads on the power side. During the production process, the plant management personnel found that the transformer and bus bar in the distribution station often had abnormal noise and vibration, and the capacitors in the two reactive power compensation cabinets were bulging and damaged.

Detection result:

(1)By checking the wiring mode of two reactive power compensation cabinets, it is found that the reactive power compensation capacitor is not equipped with reactor;
  (2) The power quality of the incoming cabinet of the distribution station is detected, and the total harmonic distortion rate is increased due to the periodic impact load;
(3) Through the comparison before and after the reactive power compensation is put into operation, the harmonic current changes obviously, and the odd harmonics are amplified in varying degrees, especially the 11th and 13th harmonics.

Power Quality Inspection(图2)
Power Quality Inspection(图3)

Customer value:

(1)Find the hidden trouble of power supply and distribution system which has been bothering customers for a long time;
(2)To provide data reference and solutions for power quality harmonic control in later period;
(3)Enhance the customer's concern about power quality, including the introduction of power quality prevention and governance scheme for future construction, technical transformation and expansion, so as to ensure the power safety of the plant and reduce the failure rate of equipment.

Harmonic content diagram
Power Quality Inspection(图4)

Case study of building materials industry

Customer issues:

The customer's equipment is mainly frequency conversion motor. There are a lot of harmonics in the 0.4kV bus, which leads to the reactor burning in the reactive power compensation cabinet and the bus heating seriously.

Detection result:

(1)The harmonic content on site has exceeded the national standard;
(2)The main harmonics are 5, 7, 11 and 13;
(3)The power factor is up to the standard.

Customer value:

(1)According to the harmonic content data in the test results, a detailed harmonic control scheme can be formulated;
(2)Provide the evaluation of the effect of power quality management after governance, and provide the basis for the completion acceptance of the power quality management project of customers.


Consultation and understanding
On-Line